EMC Considerations in Switching Power Supply Design
This one-day seminar covers radiated and conducted emission problems
associated with the design of switching power supplies. Electric
and Magnetic field coupling mechanisms are developed. Models are
developed for the various emission sources, both radiated and conducted,
and the methods of emission control are discussed. A graphical approach
to power line filter design is presented and explained. Troubleshooting
procedures and EMC requirements are also covered.
Outline
CABLING
Electric Field Coupling
Magnetic Field Coupling
Crosstalk
Cable types
Shield Terminations
RADIATED EMISSION MODELING
Radiation Mechanisms
Differential-Mode Emission
Common-Mode Emission
Methods of Controlling Radiated Emission
CONDUCTED EMISSION MODELING
Emission Sources
Common-Mode Conducted Emission
Differential-Mode Conducted Emission
Controlling Conducted Emission
Power Line Filters
Common-Mode Chokes
Leakage Inductance
Power Supply Noise Sources
Digital Logic Noise Sources
POWER LINE FILTER DESIGN
Filter Attenuation
Graphical Attenuation Method
Advantages of Graphical Design
Common-Mode Filter Design Example
TROUBLESHOOTING CONDUCTED EMISSION PROBLEMS
Measurement & Diagnostic Procedures
Differential Vs. Common Mode
Saturation
WORLDWIDE EMC REQUIREMENTS
European Union Immunity Standards
Transient Immunity
Harmonics & Flicker